Techniques in Vascular & Interventional Radiology
Volume 13, Issue 3 , Pages 167-171 , September 2010

Operator Shielding: How and Why

  • Beth A. Schueler, PhD

      Affiliations

    • Corresponding Author InformationAddress reprint requests to Beth A. Schueler, PhD, Department of Radiology, 200 First Street SW, Mayo Clinic, Rochester, MN 55905

References 

  1. Marx MV, Niklason L, Mauger EA. Occupational radiation exposure to interventional radiologists: A prospective study. J Vasc Interv Radiol. 1992;3:597–606
  2. Marshall NW, Noble J, Faulkner K. Patient and staff dosimetry in neuroradiological procedures. Br J Radiol. 1995;68:495–501
  3. Vano E, Gonzalez L, Guibelalde E, et al. Radiation exposure to medical staff in interventional and cardiac radiology. Br J Radiol. 1998;71:954–960
  4. Vano E, Gonzalez L, Fernandez JM, et al. Eye lens exposure to radiation in interventional suites: Caution is warranted. Radiology. 2008;248:945–953
  5. Whitby M, Martin CJ. A study of the distribution of dose across the hands of interventional radiologists and cardiologists. Br J Radiol. 2005;78:219–229
  6. Whitby M, Martin CJ. Radiation doses to the legs of radiologists performing interventional procedures: Are they a cause for concern?. Br J Radiol. 2003;76:321–327
  7. International Electrotechnical Commission. Medical Electrical Equipment—Part 1-3: General Requirements for Basic Safety and Essential Performance—Collateral Standard: Radiation Protection in Diagnostic X-Ray Equipment, IEC 60601-1-3. Geneva: International Electrotechnical Commission; 2008;
  8. Schueler BA, Vrieze TJ, Bjarnason H, et al. An investigation of operator exposure in interventional radiology. RadioGraphics. 2006;26:1533–1541
  9. Klein LW, Miller DL, Balter S, et al. Occupational Health hazards in the interventional laboratory: Time for a safer environment. J Vasc Interv Radiol. 2009;20:147–152
  10. Yaffe MJ, Mawdsley GE, Lilley M, et al. Composite materials for x-ray protection. Health Phys. 1991;60:661–664
  11. Dragusin O, Weerasooriya R, Jais P, et al. Evaluation of a radiation protection cabin for invasive electrophysiological procedures. Eur Heart J. 2007;28:183–189
  12. Savage C, Carlson L, Clements J, et al. Comparison of the zero gravity system to conventional lead apron for radiation protection of the interventionalist. J Vasc Interv Radiol. 2009;20:s53
  13. Pelz DM. Low back pain, lead aprons, and the angiographer. AJNR Am J Neuroradiol. 2000;21:1364
  14. Wagner LK, Archer BR. Minimizing Risks from Fluoroscopic X-Rays: Bioeffects, Instrumentation, and Examination. (ed 4). The Woodlands, TX: Partners in Radiation Management; 2004;
  15. National Academy of Sciences/National Research Council. Health risks from exposure to low levels of ionizing radiation: Phase 2, BEIR (VII, Board on Radiation Effects Research). Washington, DC: National Academies Books; 2006;
  16. National Council on Radiation Protection and Measurements. Limitation of Exposure to Ionizing Radiation, NCRP: Report Number 116. Bethesda, MD: National Council on Radiation Protection and Measurements; 1993;
  17. Worgul BV, Kundiyev YI, Sergiyenko NM, et al. Cataracts among Chernobyl clean-up workers: Implications regarding permissible eye exposures. Radiat Res. 2007;167:233–243
  18. Klein BE, Klein R, Linton KL, et al. Diagnostic x-ray exposure and lens opacities: The beaver Dam eye study. Am J Public Health. 1993;83:588–590
  19. Vano E, Gonzalez L, Beneytez F, et al. Lens injuries induced by occupational exposure in non-optimized interventional radiology laboratories. Br J Radiol. 1998;71:728–733
  20. Moore WE, Ferguson G, Rohrmann C. Physical factors determining the utility of radiation safety glasses. Med Phys. 1980;7:8–12
  21. Maeder M, Brunner-La Rocca HP, Wolbwer T, et al. Impact of a lead glass screen on scatter radiation to eyes and hands in interventional cardiologists. Catheter Cardiovasc Interv. 2006;67:18–23
  22. Stavas JM, Smith TP, DeLong DM, et al. Radiation hand exposure during restoration of flow to the thrombosed dialysis access graft. J Vasc Interv Radiol. 2006;17:1611–1617
  23. Balter S. Interventional Fluoroscopy: Physics, Technology, Safety. New York, NY: Wiley-Liss; 2001;
  24. Wagner LK, Mulhern OR. Radiation-attenuating surgical gloves: Effects of scatter and secondary electron production. Radiology. 1996;200:45–48
  25. Shortt CP, Al-Hashimi H, Malone L, et al. Staff radiation doses to the lower extremities in interventional radiology. Cardiovasc Interv Radiol. 2007;30:1206–1209
  26. Kruger R, Faciszewski T. Radiation dose reduction to medical staff during vertebroplasty: A review of techniques and methods to mitigate occupational dose. Spine. 2003;28:1608–1613
  27. Luchs JS, Rosioreanu A, Gregorius D, et al. Radiation safety during spine interventions. J Vasc Interv Radiol. 2005;16:107–111
  28. Dromi S, Wood BJ, Oberoi J, et al. Heavy metal pad shielding during fluoroscopic interventions. J Vasc Interv Radiol. 2006;17:1201–1206
  29. King JN, Champlin AM, Kelsey CA, et al. Using a sterile disposable protective surgical drape for reduction of radiation exposure to interventionalists. AJR Am J Roentgenol. 2002;178:153–157

PII: S1089-2516(10)00014-4

doi: 10.1053/j.tvir.2010.03.005

Techniques in Vascular & Interventional Radiology
Volume 13, Issue 3 , Pages 167-171 , September 2010